All
Search
Images
Videos
Shorts
Maps
News
More
Shopping
Flights
Travel
Notebook
Report an inappropriate content
Please select one of the options below.
Not Relevant
Offensive
Adult
Child Sexual Abuse
Dead
Test Electrical
GSH Electrical
Videos
Electrical Testing
Electrical
One Way Testing
R1 and R2
Electrical Testing Isolators
IR Test
GSH
Radial Sockets
GSH Electrical
Ring Circuit vs Radial Circuit
Testing
Radial Circuit Continuity Test
R1 and R2 3 Phase
Electrical Testing UK
Continuity
Testing
Continuity of Cooker Circuit
GSH
R1 and R2
Testing Socket Radial
GSH
Videos
Ir Test for Light Circuit
Testing
a Radial Circuit
Insulation Resistance Test Ring Final
Ring Terminal for Testing Harnesses
Insulation Resistance Test Rcbo
Megger Insulation Resistance Test
Radial Socket Circuit
Insulation Resistance Test
Ring Main Test
How to Test a Radial Circuit
Why R1 R2 4
One Way
Testing Lighting
ZS On a Radial SKT
Electrical Dead
Test Procedure
UK Electrical Testing
Site Temps
GSH Electrical
Training
Length
All
Short (less than 5 minutes)
Medium (5-20 minutes)
Long (more than 20 minutes)
Date
All
Past 24 hours
Past week
Past month
Past year
Resolution
All
Lower than 360p
360p or higher
480p or higher
720p or higher
1080p or higher
Source
All
Dailymotion
Vimeo
Metacafe
Hulu
VEVO
Myspace
MTV
CBS
Fox
CNN
MSN
Price
All
Free
Paid
Clear filters
SafeSearch:
Moderate
Strict
Moderate (default)
Off
Filter
Dead
Test Electrical
GSH Electrical
Videos
Electrical Testing
Electrical
One Way Testing
R1 and R2
Electrical Testing Isolators
IR Test
GSH
Radial Sockets
GSH Electrical
Ring Circuit vs Radial Circuit
Testing
Radial Circuit Continuity Test
R1 and R2 3 Phase
Electrical Testing UK
Continuity
Testing
Continuity of Cooker Circuit
GSH
R1 and R2
Testing Socket Radial
GSH
Videos
Ir Test for Light Circuit
Testing
a Radial Circuit
Insulation Resistance Test Ring Final
Ring Terminal for Testing Harnesses
Insulation Resistance Test Rcbo
Megger Insulation Resistance Test
Radial Socket Circuit
Insulation Resistance Test
Ring Main Test
How to Test a Radial Circuit
Why R1 R2 4
One Way
Testing Lighting
ZS On a Radial SKT
Electrical Dead
Test Procedure
UK Electrical Testing
Site Temps
GSH Electrical
Training
Electrical Testing
Procedure
Electrical Testing
Explained
Electrical Testing
of C6 Bulb
Electrical Testing
Tools
Electrical Testing
UK
Testing Electrical
Circuits
Live
Electrical Testing
Electrical
ZS Testing
Electrical
Continuity Testing
Electrical Testing
Equipment
Electrical
Competency Test UK
Electrical
Installation Testing
0:47
Don’t Make this Insulation Resistance Test Mistake. During this test, if the leads fail, it will give you a false reading, making it seem like you’re getting a very high insulation resistance on the circuit you're testing. Therefore, it’s crucial to test the leads before and after carrying out an insulation resistance test. #gshelectrical #electricaltrainingvideos #electricalwiring
711 views
2 months ago
TikTok
gsh_electrical
0:42
Testing an RCD to the Minimum Requirements #ElectricalTesting | GSH Electrical Training
20.2K views
May 6, 2024
Facebook
GSH Electrical Training
0:19
Testing Made Easy 👀 | GSH Electrical Training
7.7K views
10 months ago
Facebook
GSH Electrical Training
0:43
Testing Made Easy | GSH Electrical Training
4.9K views
11 months ago
Facebook
GSH Electrical Training
4:13
Don’t Fail Testing on Continuity of CPC How to test dead for continuity of the CPC and polarity of our 2 way lighting circuit in PVC conduit as we prepare for our City and Guild 5357. 2391, AM2 and AM2S. It is very important to test to all earthed parts (exposed conductive parts) of an electrical circuit and not just the screwed earth terminal. EAL Awards City & Guilds Please Note: we have plastic light fitting and PVC conduit which are fully insulated and we have metal light switch boxes and me
2K views
Jan 10, 2024
Facebook
GSH Electrical Training
1:30
3 Phase Distribution Boards - Proving Dead #electricalwiring | GSH Electrical Training
1.2K views
Mar 7, 2024
Facebook
GSH Electrical Training
0:32
Do You Do This? #electricaltesting #wiring #electricians #apprenticship #SparkingMemories #ElectriciansLife #Electricaltrainingvideos #Electrical #electricalwork #ElectricalInstallations #electricalwiring #Electrician #Electricians #gshelectrical #electrical #Wiring #OnSiteInsights #BS7671 #electricalapprentice #Apprentices #ElectricalHistory #ElectriciansOfFacebook #Testing | GSH Electrical Training
4.8K views
7 months ago
Facebook
GSH Electrical Training
6:51
Understanding Your MFT Tester - Dead Tests EAL Awards City & Guilds In this video Marcus takes a look at an electricians MFT electrical tester. Whilst training to become an electrician it is important to be able to set up your test instrument to carryout electrical tests. In this video we look at setting up your Megger MFT tester so you can carryout continuity tests measured In ohms and insulation resistance tests measures in Megohms. 🔵 Testing and Fault Finding Video Playlist https://www.youtu
9K views
Oct 26, 2023
Facebook
GSH Electrical Training
6:09
Electrical Testing and Fault Finding - Socket NOT Working for a Dishwasher Marcus and his work experience trainee Eric have been called out to a dishwasher that isn't working. On investigation through both electrical live and dead testing they find out that one of the conductor is broken. This broken conductor is causing the socket outlet for the dishwasher not to work. All the electrical tests are carried out using a Megger MFT tester. Videos are training aids for City and Guilds (C and G) and
28.8K views
Aug 25, 2024
Facebook
GSH Electrical Training
1:06
Testing for Continuity of the CPC to the Exposed Conductive Part of a Metal Light Fitting. It’s all best to take the learning from the classroom and apply it in real life. This is one of my former learners Nice Nick doing just that with this dead test. EAL Awards City & Guilds #electricaltesting #Electricaltrainingvideos #wiring #GSHElectrical #lighting #electricalwork #electricalwiring #apprenticeship #apprentice #electrical #connection #cables #electricians #testing | GSH Electrical Training
2.9K views
Jan 6, 2024
Facebook
GSH Electrical Training
7:47
Testing and Fault Finding - Low Insulation Resistance Fault - Testing at 250 and 500 Volts DC It isn't often that you can carryout the insulation resistance test will all circuit connected because of RCD protection in a consumer unit. In this video Marcus has no RCCB's or RCBO's in the consumer unit (fuse box) so he can test between all line conductor to the neutral bar, all line conductor the the earth bar and between all neutral and earth connections. Marcus shows how using 250 volts DC from h
11.4K views
Jan 19, 2025
Facebook
GSH Electrical Training
7:39
Testing and Fault Finding - Low Insulation Resistance Fault - Testing at 250 and 500 Volts DC It isn't often that you can carryout the insulation resistance test will all circuit connected because of RCD protection in a consumer unit. In this video Marcus has no RCCB's or RCBO's in the consumer unit (fuse box) so he can test between all line conductor to the neutral bar, all line conductor the the earth bar and between all neutral and earth connections. Marcus shows how using 250 volts DC from h
11.8K views
Aug 26, 2024
Facebook
GSH Electrical Training
3:41
R1R2 Link Makes Testing for Continuity of the CPC Faster and Easier Especially Whilst Training The R1R2 link will make carrying out the continuity of CPC test faster, easier and will reduce the number of times the line conductors needs removing for a circuit breaker (MCB). Over my years of teaching apprentice electricians I have changed the way in which I link the line to the CPC during dead testing. I started out disconnecting the line conductor and using a crocodile link to connect it to the e
6.4K views
Jul 29, 2024
Facebook
GSH Electrical Training
2:09
The Challenges of Testing Exposed Conductive Parts In this video, we will demonstrate how to perform the dead tests on our one-way lighting circuit, which is wired with PVC singles in a plastic conduit. I will show you how to ensure that the exposed conductive parts of a metal grid switch are properly connected to the CPC (Earth). Continuity of the CPC & Insulation Resistance Tests Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E. You c
14.5K views
Jan 12, 2025
Facebook
GSH Electrical Training
4:19
R1R2 Link Makes Testing for Continuity of the CPC Faster and Easier Especially Whilst Training The R1R2 link will make carrying out the continuity of CPC test faster, easier and will reduce the number of times the line conductors needs removing for a circuit breaker (MCB). Over my years of teaching apprentice electricians I have changed the way in which I link the line to the CPC during dead testing. I started out disconnecting the line conductor and using a crocodile link to connect it to the e
10.1K views
Jan 2, 2025
Facebook
GSH Electrical Training
9:08
Testing Continuity of CPC, Polarity & Insulation Resistance of a 2 Way Lighting Circuit PVC Conduit How to test dead for continuity of the CPC, insulation resistance and polarity of our 2 way lighting circuit in PVC conduit as we prepare for our City and Guild 5357 practical assessment 107 and AM2S. Please Note: we have plastic light fitting and PVC conduit are which are fully insulated and we have metal light switch boxes and metal plates making them exposed conductive parts. Videos are trainin
1.6K views
Aug 22, 2024
Facebook
GSH Electrical Training
8:26
Updated Guidance on Testing Hager Type ‘A’ RCCB’s (What to do if they Fail 5x 30mA (150mA) Test. When testing an A type Hager RCCB for additional protection you may have to test at 5x 50mA (250mA) if when testing at 5x 30mA (150mA) the disconnection time exceeds 40mS. The link below is the how to guidance from Hager. Remember updates from manufacturers can change or be updated at anytime so always look for the latest information. https://www.hager.co.uk/news-exhibitions-case-studies/18th-edition
12.1K views
Aug 16, 2024
Facebook
GSH Electrical Training
0:39
External Earth Fault Loop Impedance Test (Ze) #electricalwork #electricalwiring #gshelectrical | GSH Electrical Training
17.1K views
4 months ago
Facebook
GSH Electrical Training
7:03
Why Testing Grid Switches Can Be a Nightmare for Electricians 1 Way Lighting Circuit Wired in Conduit - Continuity of the CPC & Insulation Resistance Tests In this video we look at carrying out the dead tests on our 1 way lighting circuit wired in PVC singles in a plastic conduit exercise. I demonstrate how to set up my Megger MFT tester and then carryout the continuity of CPC test and include the polarity test at the same time. Next I go on to demonstrate how to carryout the insulation resistan
12.5K views
Jan 13, 2025
Facebook
GSH Electrical Training
0:16
Dangerous Socket Wiring | GSH Electrical Training
58.9K views
Nov 24, 2024
Facebook
GSH Electrical Training
0:51
Doubling Conductor Ends 👀 | GSH Electrical Training
83.8K views
Jan 5, 2025
Facebook
GSH Electrical Training
0:58
Overhead Cables Have Rules… | GSH Electrical Training
21.4K views
Feb 2, 2025
Facebook
GSH Electrical Training
0:56
Electrical End Point Assessment AM2S - What Bends are Required in Steel and PVC Conduit 📺 YouTube channels 👇🏻 🔵 https://youtube.com/c/GSHElectrical 🔵 🔴 https://youtube.com/c/efixx 🔵 | GSH Electrical Training
723 views
Nov 3, 2021
Facebook
GSH Electrical Training
0:40
LED Downlight Disaster 👀 | GSH Electrical Training
408.7K views
Oct 8, 2024
Facebook
GSH Electrical Training
14:24
How to Test a Ring Final Circuit - Ring Main or Socket Circuit - Ring Continuity & Polarity Tests SparkSafe In this video me and Marcus look at dead test number 2 in BS7671. In the test sequence this is "testing continuity of ring final circuit conductors, including protective conductors". We go through all 3 stages recording the results and we show the calculation for R1 RN and R1 R2 from r1, rn and r2 end to end readings. We prove the circuit is wired as a ring final circuit sometimes called a
11.3K views
Apr 1, 2024
Facebook
GSH Electrical Training
20:21
BASIC AUTOMOTIVE ELECTRICAL DIAGNOSIS PART 1
191.5K views
Dec 16, 2020
YouTube
Rustbelt Mechanic
17:19
Proving Dead - Mains Electricity
315.1K views
Feb 17, 2015
YouTube
John Ward (jwflame)
8:20
Electrical Channel - Testing Sequence - Dead
122.6K views
Mar 20, 2017
YouTube
Warrington & Vale Royal College Electrical Trai…
8:31
Electrical Installation Testing Introduction
353.3K views
Dec 9, 2016
YouTube
John Ward (jwflame)
4:42
Safe isolation test
105K views
Oct 19, 2011
YouTube
RoutledgeElectrical
See more
More like this
Feedback